Aquarian Level Probe and Column

Fossil Power Systems’ level probe and column are designed for steam/water level measurements using conductivity type electronic level detection systems. The probe and column are typically used with Fossil’s Aquarian line of level systems. However, these are also fully compatible with any existing electronic systems from Clark-RelianceTM, HydrastepTM, or similar manufacturers. Fossil’s probe and column provide an excellent opportunity to replace leaking probe gaskets, failed probes, and corroded columns with superior technology. The use of a junction box that is pre-wired to the probes makes…

Continue reading »

High Pressure Ported Boiler Level Gauge Repair Kits

Fossil Power Systems’ offers several Ported Boiler Level Gauge Repair Kit configurations to fit Fossil and Yarway gauge designs. All repair kits use the very best high quality materials and are rated for 3000 psi saturated steam service. The Repair Kit consists of the following 5 components as shown in the above photo: (1) Cushion Gasket: • High temperature Graphoil (2) Window: • Precision ground Aluminosilicate glass (3) Mica: • Premium V-1 quality clear ruby muscovite (4) Sealing Gasket: • Laminated and die-formed graphoil (5)…

Continue reading »

High Integrity Brazed Joint Probe

Fossil Steam Technologies’ (FST) Brazed Probes are now available to retrofit* Clark-RelianceTM model FG, ZG, V and T probes. The brazed technology is well proven with more than 60,000 probes in service worldwide. The brazed insulator to body union provides a reliable high pressure, high temperature seal, that rewards the user with long term performance, thereby minimizing maintenance and associated operating costs. “once and you’re done” • High density zirconium-wetted insulator improves steam and water detection through minimized contaminant buildup and enhanced water shedding. The…

Continue reading »

Warranty, Technical, and Pricing Information. Aquarian Products Update – Purchase, Support & Warranty

For over 17 years, more than 4000 system owners world-wide have trusted Fossil Power Systems’ (Fossil) Aquarian products for accurate water detection. During the earlier years, Aquarian products were marketed and distributed exclusively by YarwayTM Corp. for Fossil. The Aquarian product line and spare parts are now being sold and supported directly by the manufacturer and designer, Fossil Power Systems. At Fossil, we remain committed to the Aquarian product innovation and seamless service that has made us a global leader. Our Aquarian products and support…

Continue reading »

Retrofit LED Illuminator To fit YarwayTM Color-Port® Gauge

Reduce plant maintenance by replacing your outdated bulb illuminator with state-of-the-art LED technology. This patented design will provide years of maintenance-free service. The ASME Boiler and Pressure Vessel Code states that “ported gages or endconnected strip gages, shall be equipped to afford obvious visual discrimination between the appearance of water or vapor in the individual sections.” The Solid State Bi-Colour Gauge Illuminator and Display attach to the ported visual gauge to produce a red or green image on the display. A red image indicates that…

Continue reading »

Aquarian 4-20 mA and RS-485 Serial Module

The Aquarian 3000 Mini Analog 4-20 mA Interface Module is an intelligent I/O card designed to provide an isolated 4-20 mA analog signal. The output is an anolog representation of the height of water in the column. The water height is determine by the existing logic in the Aquarian 3000 Mini system (see Aquarian 3000Mini brochure 9340-1103). The Module also has a 3-wire RS-485 Serial Output link to drive Aquarian 3000 Mini Remote Display indicators. Integrity is assured with watchdog logic that is independent of…

Continue reading »

Aquarian 3000Visual Closed Circuit TV Camera (CCTV Camera)

The Aquarian 3000Visual CCTV Colour Camera is used to remotely monitor the level of the AQ3000V bi-colour water level gauge, or other similar equipment. The camera meets the ASME Boiler and Pressure Vessel Code PG-60 requirements for “an independent continuous transmission and display of an image of the water level in a gage glass”. This high quality industrial camera provides clear and accurate colour transmission in both indoor and outdoor applications. The optical and digital zoom, adjustable focus, and 3-axis swivel adjustment permits flexible camera…

Continue reading »

Aquarian Level Gauge Isolation Valves

Fossil Power Systems offers a variety of high quality valves designed for visual level gauge isolation. All valves are forged steel and constructed to meet the rigorous demands of high pressure steam boiler service. The valves meet the requirements of the ASME Boiler and Pressure Vessel Code, Section 1. GV3100 1” angled globe valve ¾” flanged gauge connections Conval Clampseal body construction Pressure seal threaded bonnet/yoke Rated Class 2155 Outside screw and yoke (OS & Y) construction SA-105 Forged Steel body and yoke, Nickel Plated…

Continue reading »

Aquarian 3000Visual Bi-Colour Gauge Illuminator Series 2 and Display

The Aquarian 3000Visual is a high pressure ported water level gauge used to measure the water level in high-pressure boiler steam drums. The ASME Boiler and Pressure Vessel Code states that “ported gages or end-connected strip gages, shall be equipped to afford obvious visual discrimination between the appearance of water or vapor in the individual sections.” The Solid State Bi-Colour Gauge Illuminator and Display attach to the 3000 psi ported gauge to produce a red or green image on the display. A red image indicates…

Continue reading »

Aquarian 3000Visual Bi-colour Water Level Gauge

The Aquarian 3000Visual is a 3000 psi ported gauge that produces a red/green image to indicate the water level in a high-pressure steam drum. The body is precision machined into a trapezoidal shape. Light projected through steam produces a red image. Light projected through water is refracted (bent) and produces a green image. The gauge fulfills the requirements in the 2001 ASME Boiler and Pressure Vessel Code Section 1 PG-60.1 that states: “Boiler with an MAWP of 400 psi or less and electric boilers of…